Hybrid/EV Battery Precharge Contactor Circuit Stuck Open


Table of contents

P0AE3 SATURN Possible Causes

  • Faulty Battery Energy Control Module
  • Battery Energy Control Module harness is open or shorted
  • Battery Energy Control Module circuit poor electrical connection

How do I fix code P0AE3 SATURN?

  Check the “Possible Causes” listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector’s pins.

Cost of diagnosing the P0AE3 SATURN code

  The cost of diagnosing the P0AE3 SATURN code is 1.0 hour of labor. The auto repair labor rates vary by location, your vehicle’s make and model, and even your engine type. Most auto repairs shops charge between $75 and $150 per hour.

Possible Symptoms

  • Engine Light ON (or Service Engine Soon Warning Light)

P0AE3 SATURN Description

  The hybrid/EV battery contains 4 high voltage contactors and 1 solid state relay (transistor). The high voltage contactors and transistor allow the high voltage DC batteries to be connected to the vehicle or contain the high voltage DC within the hybrid/EV battery assembly. The 4 high voltage contactors consist of a main positive high voltage contactor, main negative high voltage contactor, charge positive high voltage contactor and a precharge negative high voltage contactor. The transistor controls the battery heater high voltage positive circuit. The contactors and transistor close and open in a specific sequence controlled by the hybrid/EV powertrain control module 2. The hybrid/EV powertrain control module 2 supplies voltage to the control circuit for each high voltage contactor/transistor. Ground is provided through a vehicle ground external of the high voltage battery.