Voltage Control Unit Low Side Open Fail
Table of contents
P1DA2 HONDA Possible Causes
- Faulty Voltage Control Unit (VCU)
- Voltage Control Unit (VCU) harness is open or shorted
- Voltage Control Unit (VCU) circuit poor electrical connection
- Faulty Motor Control Module (Generator)
How do I fix code P1DA2 HONDA?
Check the “Possible Causes” listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector’s pins.
Cost of diagnosing the P1DA2 HONDA code
The cost of diagnosing the P1DA2 HONDA code is 1.0 hour of labor. The auto repair labor rates vary by location, your vehicle’s make and model, and even your engine type. Most auto repairs shops charge between $75 and $150 per hour.
Possible Symptoms
- Engine Light ON (or Service Engine Soon Warning Light)
P1DA2 HONDA Description
If the low side of Voltage Control Unit (VCU) has open-malfunction, the V2 voltage drops because voltage increase control cannot be performed as commanded, so the VCU low side is judged as abnormal output, and the motor control module (generator) detects a malfunction and stores a DTC.